To check UCSM faults summary for all severity

ucspe# show fault
Severity  Code     Last Transition Time     ID       Description
--------- -------- ------------------------ -------- -----------
Warning   F16976   2016-11-02T13:14:48.685   3413419 [FSM:STAGE:RETRY:]: Cleaning up CIMC configuration for server sys/rack-unit-1(FSM-STAGE:sam:dme:ComputePhysicalDecommission:CleanupCIMC)
Warning   F16976   2016-11-02T13:09:48.682   3413469 [FSM:STAGE:RETRY:]: Cleaning up CIMC configuration for server sys/chassis-1/blade-1(FSM-STAGE:sam:dme:ComputePhysicalDecommission:CleanupCIMC)
Warning   F78434   2016-11-02T10:21:29.138   3413241 [FSM:STAGE:REMOTE-ERROR]: Result: end-point-protocol-error Code: unspecified Message: Error retrieving Server Params-MC Error(-1): (sam:dme:Comp
uteRackUnitDiscover:BmcInventory)

To display the faults related to particular severity. Below displayed only the major faults likewise can be done for other severity like critical, minor, warnings etc.,

ucspe# show fault severity major
Severity  Code     Last Transition Time     ID       Description
--------- -------- ------------------------ -------- -----------
Major     F0209    2016-11-02T10:15:26.672   3413225 Adapter uplink interface 4/1/1 link state: unavailable. Please verify connectivity to Fabric Interconnect. Acknowledging FEX might be required.
Major     F0209    2016-11-02T10:15:26.671   3413224 Adapter uplink interface 4/1/2 link state: unavailable. Please verify connectivity to Fabric Interconnect. Acknowledging FEX might be required.
Major     F0209    2016-11-02T10:15:26.668   3413222 Adapter uplink interface 3/1/1 link state: unavailable. Please verify connectivity to Fabric Interconnect. Acknowledging FEX might be required.
Major     F0209    2016-11-02T10:15:26.666   3413221 Adapter uplink interface 3/1/2 link state: unavailable. Please verify connectivity to Fabric Interconnect. Acknowledging FEX might be required.
Major     F0209    2016-11-02T10:15:26.655   3413217 Adapter uplink interface 1/8/2/1 link state: unavailable. Please verify connectivity to Fabric Interconnect. Acknowledging chassis might be requ
ired.
Major     F0209    2016-11-02T10:15:26.654   3413216 Adapter uplink interface 1/8/2/3 link state: unavailable. Please verify connectivity to Fabric Interconnect. Acknowledging chassis might be requ
ired.

To check UCSM date and time

ucspe# show clock
Wed Nov  2 13:58:31 UTC 2016

To check UCS fabric interconnect cluster status

ucspe# show cluster state 
Cluster Id: 0x7163814ea06911e6-0x8aed000c29428154

A: UP, PRIMARY
B: UP, SUBORDINATE

HA READY
ucspe# show cluster extended-state
Cluster Id: 0x7163814ea06911e6-0x8aed000c29428154

Start time: Tue Nov  1 19:29:09 2016
Last election time: Tue Nov  1 19:29:17 2016

A: UP, PRIMARY
B: UP, SUBORDINATE

A: memb state UP, lead state PRIMARY, mgmt services state: UP
B: memb state UP, lead state SUBORDINATE, mgmt services state: UP
   heartbeat state PRIMARY_OK

INTERNAL NETWORK INTERFACES:
eth0, UP

HA READY
Detailed state of the device selected for HA storage:
Chassis 1, serial: CH1, state: active
Chassis 2, serial: CH2, state: active
Server 1, serial: RK1, state: active

NO COMMENTS

LEAVE A REPLY